Have any question ? +44 2030 2627 92

ISSN: 3033-3555 | Open Access

Journal of Stomatology & Dental Research

Volume : 3 Issue : 3

Periimplantitis Surface Decontamination and Integrity Following Use of Co2 Laser or Water Irrigation and Mechanical Therapy: A Comparison Study

Scott H Froum*, Stuart J Froum , Ahmed Youssef Gamal  and Khaled Abdel Ghaffar

ABSTRACT

Objective: The primary aim of this study was to evaluate and compare the effects of Carbon dioxide (Co2) laser or mechanical therapy and water irrigation on dislodgement of surface deposits, surface decontamination and surface integrity of bacterially contaminated implant surfaces.

Background: Currently, there is a lack of evidence about optimal surface decontamination for implants affected with peri-implantitis.This study compares these two methods of surface decontamination on two implants which were explanted due to bone loss caused by periimplantitis.

Method: This in-vitro comparison study was performed on two failed dental implants that were affected by advanced levels of peri-implantitis and required explanation. Two periimplantitis affected implants were removed with one treated with mechanical cleaning and saline irrigation and the other with high-power laser irradiation using a 1.0mm spot size, 60% cutting speed and energy output of 13.9 watt (w) 100% mist for
one minute. Post treatment, both implants were dehydrated, mounted on aluminum studs and gold plated for surface topography and surface disinfection level Scanning electron microscope (SEM) evaluation.

Results: High power laser treatment for one minute showed no deposits attached to the implant surface. The entire surface appeared intact with no surface scratches and no adherent bacterial colonies. The mechanical and water treated implants showed deposits still adherent to the implant surface with multiple areas of implant surface scratches and surface distortion.

Conclusions: A 9.3-micron Co2 laser setting used with a high-power setting of 1.0mm spot size, 60% cutting speed, 100% mist and an energy output of 13.9w for one minute could be a safe effective setting providing maximum antiplaque effect with minimum to no effects on implant surface integrity. Mechanical hand cleaning with saline irrigation was not effective in removing all biofilm and left scratches on the implant surface.